Articles

KLSTR.one Integration Guide

Hardware and network integration guide for the KLSTR.one device — Ethernet, DMX, Art-Net/sACN configuration, and dual-mode operation with KLSTR.nano.

By KLSTR Engineering · 2026-04-15 KLSTR.one Plug-In Integration integration hardware manufacturer

KLSTR.one Integration Guide

Overview

The KLSTR.one is a standalone Ethernet-to-DMX gateway with full Art-Net, sACN, and RDM support. This document covers the integration of KLSTR.one into lighting fixtures and systems.

Physical Interfaces

The KLSTR.one provides the following interfaces:

InterfaceConnectorDescription
EthernetRJ4510/100 Mbps, supports PoE (802.3af)
DMX OUTXLR 5-pinDMX512-A output with RDM support
DMX INXLR 5-pinDMX512-A input for daisy-chain
PowerBarrel jack12–48 V DC, 5 W typical
USB-CUSB Type-CConfiguration and firmware updates

Network Integration

Art-Net Configuration

The KLSTR.one supports Art-Net 4 with the following capabilities:

  • Up to 4 Art-Net universes per device
  • Art-Net polling and reply for automatic discovery
  • RDM over Art-Net (Art-RDM) for remote fixture management
  • Configurable Art-Net subnet and universe mapping

sACN Configuration

sACN (E1.31) is supported with:

  • Priority-based merging (HTP and LTP modes)
  • Multicast and unicast operation
  • Universe synchronization
  • Per-universe priority assignment

Dual-Mode Operation

When used together with KLSTR.nano modules inside a fixture, the KLSTR.one operates in dual mode:

  1. The KLSTR.one handles Ethernet-side protocol conversion (Art-Net/sACN).
  2. The KLSTR.nano handles DMX-side communication with the fixture's internal controller.
  3. Communication between the two modules uses the DMX_LAN interface.

Dual-Mode Wiring

Connect the KLSTR.one to the KLSTR.nano using the following pin mapping:

KLSTR.one PinSignalKLSTR.nano Pin
DMX LAN A+RS485 A+Pin 23 (DMX_LAN_A)
DMX LAN B−RS485 B−Pin 22 (DMX_LAN_B)
GNDGroundPin 21 (GND)
Heartbeat OUTStatusPin 35 (PC2)

Mechanical Integration

The KLSTR.one is designed for both internal and external mounting:

  • Internal mount: M3 mounting holes on 4 corners, 60 × 45 mm footprint
  • External mount: DIN rail clip (optional accessory) or panel-mount bracket
  • Operating temperature: −10 °C to 50 °C
  • Protection rating: IP20 (indoor use)

Power Requirements

ParameterMinimumTypicalMaximumUnit
Supply voltage (barrel)122448V DC
Supply voltage (PoE)374857V DC
Power consumption58W
Inrush current1.5A

Document Changelog

VersionScopeDate
1.0Initial Release2026-04-15
Copyright © 2026